Gas Detection InstrumentsFAMILY / GAS-007
YT-95H / YT-95H-X Fixed Gas Detector
Fixed gas-detector platform with percentage-LEL or gas-specific sensors and analog, Modbus and relay outputs.
Source-listed reference data
Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.
Single-product and multi-line requests use the same human-reviewed workflow.
01
Product overview
What this sourcing family is designed to organize.
The YT-95H family is offered with gas-specific sensors and wall, pipe or flow-cell mounting. Source-listed variants include combustible-gas measurement with 4–20 mA, RS485 and relay outputs. Exact range, enclosure and certification depend on the selected model.
Gas Detection
02
Reference configurations
Intake categories from the linked source, pending exact model and SKU mapping.
01YT-95HSource reviewed
02YT-95H-XSource reviewed
03
Technical specifications
Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.
Attribute
Catalog value
Verification basis
Accuracy / sensitivity
YT-95H-X up to ±2% FS; YT-95H-H2 source range ±2–3% FS
Source-listed — supplier confirmation required
Alarm / output
3-wire 4–20 mA, RS485 Modbus and relays; optional audible and visual alarm above 90 dB
Source-listed — supplier confirmation required
Housing / ingress protection
Die-cast aluminium body; aluminium-alloy or 316 stainless-steel sensor housing; IP65
Source-listed — supplier confirmation required
Installation / sampling
G1/2 external thread and M45 × 2 mm entry; wall, pipe or flow-cell mounting depending on version
Source-listed — supplier confirmation required
Measurement range
YT-95H-H2 combustible configuration 0–100% LEL; YT-95H-X range specified by gas, including LEL, oxygen, VOC and toxic-gas options
Source-listed — supplier confirmation required
Product type
Fixed gas detector and transmitter
Source-listed — supplier confirmation required
RFQ verification check
Select YT-95H or YT-95H-X, identify the gas and range, and confirm the enclosure material, mounting type, relay function and certificate
Source-listed — supplier confirmation required
Source brand
Safegas
Source-listed — supplier confirmation required
Source model
YT-95H / YT-95H-X
Source-listed — supplier confirmation required
Source-listed certification
Source-listed Ex d IIC T6 Gb for the YT-95H-X data sheet; scope is not independently verified
Source-listed — supplier confirmation required
Supply / battery
12–36 VDC in the data sheet; another source lists 24 VDC nominal
Source-listed — supplier confirmation required
04
Inputs to include in the RFQ
The more of these inputs you can provide, the fewer rounds of clarification are needed.
01Target gas and expected concentration rangeRFQ input template Technical document pending
02Portable or fixed installation requirementRFQ input template Technical document pending
03Alarm, relay and control-system interfaceRFQ input template Technical document pending
04Required hazardous-area and calibration documentationRFQ input template Technical document pending
TECHNICAL PURCHASING Q&A
YT-95H / YT-95H-X Fixed Gas Detector — procurement FAQs
Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.
01How should YT-95H, YT-95H-X and their mounting options be requested?
State the target gas, measuring range, exact model suffix, mounting method and required outputs before asking for equivalence. The family is source-listed with gas-specific configurations and 4–20 mA, RS485 or relay options, so the quotation must show the actual sensor, output combination, power, enclosure, calibration accessories and hazardous-area documents for the proposed variant.
02What must be specified before selecting the sensor and alarm setpoints?
State the target gas, expected concentration and units, possible cross-interferences, background atmosphere, temperature and humidity. Alarm setpoints must come from the approved site risk assessment and applicable requirements, not from a generic catalogue default.
03How should analog, digital and relay outputs be compared?
Start with the receiving system rather than the detector. Record the required 4–20 mA input, RS485 protocol and register map, relay action or alarm-panel interface, along with power, cable distance and failure behaviour. Confirm that the selected transmitter supports the requested output combination simultaneously.
04What calibration and installation evidence should accompany the quote?
Ask for the exact sensor, range, calibration certificate or basis, recommended bump-test and calibration interval, power and output details, enclosure protection and service-access requirements. For fixed equipment, also request the proposed mounting location and hazardous-area documentation needed for review.