Gas Detection InstrumentsFAMILY / GAS-004
Dräger Pac 8000 Single-Gas Detector
Personal single-gas detector platform for selected toxic gases, oxygen and carbon dioxide, with configurable alarm and data functions.
Source-listed reference data
Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.
Single-product and multi-line requests use the same human-reviewed workflow.
01
Product overview
What this sourcing family is designed to organize.
The Pac 8000 is a personal detector that can be ordered with a gas-specific sensor. Source-listed ranges cover several toxic gases plus carbon dioxide, and the enclosure is rated IP68. Sensor choice, calibration and certificate scope determine the usable configuration.
Gas Detection
02
Reference configurations
Intake categories from the linked source, pending exact model and SKU mapping.
01Pac 8000Source reviewed
03
Technical specifications
Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.
Attribute
Catalog value
Verification basis
Accuracy / sensitivity
Sensor-specific accuracy is not listed in the reviewed summary
Source-listed — supplier confirmation required
Alarm / output
360° visual and audible alarms, D-light, TLV/STEL alarm functions and Bluetooth
Source-listed — supplier confirmation required
Housing / ingress protection
IP68
Source-listed — supplier confirmation required
Installation / sampling
Personal diffusion monitor
Source-listed — supplier confirmation required
Measurement range
Sensor dependent: NO 0–200 ppm; CO2 0–5 vol%; Cl2 0–20 ppm; HCN 0–50 ppm; NH3 0–300 ppm; PH3 0–20 ppm; OV/OV-A 0–200 ppm; NO2 0–50 ppm; other gases available
Source-listed — supplier confirmation required
Product type
Portable single-gas detector
Source-listed — supplier confirmation required
RFQ verification check
Confirm the gas, range, alarm setpoints, calibration certificate, battery condition and approved hazardous-area marking
Source-listed — supplier confirmation required
Source brand
Dräger
Source-listed — supplier confirmation required
Source model
Pac 8000
Source-listed — supplier confirmation required
Source-listed certification
Source-listed ATEX, IECEx, CSA and EAC ranges; exact marking must follow the selected sensor and model variant
Source-listed — supplier confirmation required
Supply / battery
Two-year battery service life listed by the source
Source-listed — supplier confirmation required
04
Inputs to include in the RFQ
The more of these inputs you can provide, the fewer rounds of clarification are needed.
01Target gas and expected concentration rangeRFQ input template Technical document pending
02Portable or fixed installation requirementRFQ input template Technical document pending
03Alarm, relay and control-system interfaceRFQ input template Technical document pending
04Required hazardous-area and calibration documentationRFQ input template Technical document pending
01How should the Dräger Pac 8000 gas and sensor variant be specified?
A Pac 8000 must be ordered for one defined gas, oxygen or carbon dioxide measurement rather than selected from the family name alone. Provide the target gas, expected concentration and units, alarm strategy and work-area context. The quote should identify the exact sensor code, measuring range, alarm configuration, calibration evidence, regional approval and data or docking accessories needed for the site's procedure.
02What must be specified before selecting the sensor and alarm setpoints?
State the target gas, expected concentration and units, possible cross-interferences, background atmosphere, temperature and humidity. Alarm setpoints must come from the approved site risk assessment and applicable requirements, not from a generic catalogue default.
03How should analog, digital and relay outputs be compared?
Start with the receiving system rather than the detector. Record the required 4–20 mA input, RS485 protocol and register map, relay action or alarm-panel interface, along with power, cable distance and failure behaviour. Confirm that the selected transmitter supports the requested output combination simultaneously.
04What calibration and installation evidence should accompany the quote?
Ask for the exact sensor, range, calibration certificate or basis, recommended bump-test and calibration interval, power and output details, enclosure protection and service-access requirements. For fixed equipment, also request the proposed mounting location and hazardous-area documentation needed for review.