Illustrative image. Exact appearance, accessories, finish and markings must be confirmed against the quoted model.
Gas Detection InstrumentsFAMILY / GAS-002
BH90E Portable Gas Leak Detector
Compact combustible-gas leak detector with audible, visual and vibration alarms for inspection and maintenance teams.
Source-listed reference data
Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.
Single-product and multi-line requests use the same human-reviewed workflow.
01
Product overview
What this sourcing family is designed to organize.
The BH90E is configured for combustible-gas leak inspection in the ppm range. The reviewed source lists a 0–10,000 ppm range, default alarm points, rechargeable battery and an intrinsically-safe design statement without a model-specific Ex rating.
Gas Detection
02
Reference configurations
Intake categories from the linked source, pending exact model and SKU mapping.
01BH90ESource reviewed
03
Technical specifications
Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.
Attribute
Catalog value
Verification basis
Accuracy / sensitivity
Not stated in the reviewed source
Source-listed — supplier confirmation required
Alarm / output
Buzzer, LED and vibration alarms; default low alarm 500 ppm and high alarm 2,000 ppm
Source-listed — supplier confirmation required
Housing / ingress protection
Not stated in the reviewed source
Source-listed — supplier confirmation required
Installation / sampling
Natural diffusion
Source-listed — supplier confirmation required
Measurement range
Combustible gas 0–10,000 ppm (μmol/mol)
Source-listed — supplier confirmation required
Product type
Portable combustible-gas leak detector
Source-listed — supplier confirmation required
RFQ verification check
Confirm the target gas, alarm setpoints, calibration gas, battery configuration and required hazardous-area certificate
Source-listed — supplier confirmation required
Source brand
Bosean
Source-listed — supplier confirmation required
Source model
BH90E
Source-listed — supplier confirmation required
Source-listed certification
Source states intrinsically-safe and explosion-proof design but provides no model-specific Ex marking
Source-listed — supplier confirmation required
Supply / battery
Rechargeable DC 3.7 V, 1,800 mAh battery; at least 8 hours; charging 6–8 hours
Source-listed — supplier confirmation required
04
Inputs to include in the RFQ
The more of these inputs you can provide, the fewer rounds of clarification are needed.
01Target gas and expected concentration rangeRFQ input template Technical document pending
02Portable or fixed installation requirementRFQ input template Technical document pending
03Alarm, relay and control-system interfaceRFQ input template Technical document pending
04Required hazardous-area and calibration documentationRFQ input template Technical document pending
TECHNICAL PURCHASING Q&A
BH90E Portable Gas Leak Detector — procurement FAQs
Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.
01What should be confirmed about the BH90E range, alarm and certification?
The reviewed BH90E source lists a 0–10,000 ppm range and audible, visual and vibration alarms, but a general intrinsically-safe statement does not replace a model-specific hazardous-area certificate. Confirm the exact gas and sensor, alarm points, calibration gas, Ex marking, destination-market acceptance and availability of filters or spare sensors before ordering.
02What must be specified before selecting the sensor and alarm setpoints?
State the target gas, expected concentration and units, possible cross-interferences, background atmosphere, temperature and humidity. Alarm setpoints must come from the approved site risk assessment and applicable requirements, not from a generic catalogue default.
03How should analog, digital and relay outputs be compared?
Start with the receiving system rather than the detector. Record the required 4–20 mA input, RS485 protocol and register map, relay action or alarm-panel interface, along with power, cable distance and failure behaviour. Confirm that the selected transmitter supports the requested output combination simultaneously.
04What calibration and installation evidence should accompany the quote?
Ask for the exact sensor, range, calibration certificate or basis, recommended bump-test and calibration interval, power and output details, enclosure protection and service-access requirements. For fixed equipment, also request the proposed mounting location and hazardous-area documentation needed for review.