Industrial instrumentation sourcing · Contact us on WhatsAppProcess, gas and airflow instruments · Review status clearly marked
Gas Detection InstrumentsFAMILY / GAS-002

BH90E Portable Gas Leak Detector

Compact combustible-gas leak detector with audible, visual and vibration alarms for inspection and maintenance teams.

Source-listed reference data

Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.

Product family ID
GAS-002
Internal family code
GAS-BH90E
Application route
Gas Detection
Commercial status
Quote on verified requirement

Single-product and multi-line requests use the same human-reviewed workflow.

01

Product overview

What this sourcing family is designed to organize.

The BH90E is configured for combustible-gas leak inspection in the ppm range. The reviewed source lists a 0–10,000 ppm range, default alarm points, rechargeable battery and an intrinsically-safe design statement without a model-specific Ex rating.

Gas Detection
02

Reference configurations

Intake categories from the linked source, pending exact model and SKU mapping.

01BH90ESource reviewed
03

Technical specifications

Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.

AttributeCatalog valueVerification basis
Accuracy / sensitivityNot stated in the reviewed sourceSource-listed — supplier confirmation required
Alarm / outputBuzzer, LED and vibration alarms; default low alarm 500 ppm and high alarm 2,000 ppmSource-listed — supplier confirmation required
Housing / ingress protectionNot stated in the reviewed sourceSource-listed — supplier confirmation required
Installation / samplingNatural diffusionSource-listed — supplier confirmation required
Measurement rangeCombustible gas 0–10,000 ppm (μmol/mol)Source-listed — supplier confirmation required
Product typePortable combustible-gas leak detectorSource-listed — supplier confirmation required
RFQ verification checkConfirm the target gas, alarm setpoints, calibration gas, battery configuration and required hazardous-area certificateSource-listed — supplier confirmation required
Source brandBoseanSource-listed — supplier confirmation required
Source modelBH90ESource-listed — supplier confirmation required
Source-listed certificationSource states intrinsically-safe and explosion-proof design but provides no model-specific Ex markingSource-listed — supplier confirmation required
Supply / batteryRechargeable DC 3.7 V, 1,800 mAh battery; at least 8 hours; charging 6–8 hoursSource-listed — supplier confirmation required
04

Inputs to include in the RFQ

The more of these inputs you can provide, the fewer rounds of clarification are needed.

01Target gas and expected concentration rangeRFQ input template
Technical document pending
02Portable or fixed installation requirementRFQ input template
Technical document pending
03Alarm, relay and control-system interfaceRFQ input template
Technical document pending
04Required hazardous-area and calibration documentationRFQ input template
Technical document pending
TECHNICAL PURCHASING Q&A

BH90E Portable Gas Leak Detector — procurement FAQs

Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.

01What should be confirmed about the BH90E range, alarm and certification?

The reviewed BH90E source lists a 0–10,000 ppm range and audible, visual and vibration alarms, but a general intrinsically-safe statement does not replace a model-specific hazardous-area certificate. Confirm the exact gas and sensor, alarm points, calibration gas, Ex marking, destination-market acceptance and availability of filters or spare sensors before ordering.

02What must be specified before selecting the sensor and alarm setpoints?

State the target gas, expected concentration and units, possible cross-interferences, background atmosphere, temperature and humidity. Alarm setpoints must come from the approved site risk assessment and applicable requirements, not from a generic catalogue default.

03How should analog, digital and relay outputs be compared?

Start with the receiving system rather than the detector. Record the required 4–20 mA input, RS485 protocol and register map, relay action or alarm-panel interface, along with power, cable distance and failure behaviour. Confirm that the selected transmitter supports the requested output combination simultaneously.

04What calibration and installation evidence should accompany the quote?

Ask for the exact sensor, range, calibration certificate or basis, recommended bump-test and calibration interval, power and output details, enclosure protection and service-access requirements. For fixed equipment, also request the proposed mounting location and hazardous-area documentation needed for review.