Gas Detection InstrumentsFAMILY / GAS-008

BH-60 Fixed Gas Detector

Wall-mounted fixed gas detector with local display and analog, Modbus and contact outputs.

Source-listed reference data

Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.

Product family ID
GAS-008
Internal family code
GAS-BH60
Application route
Gas Detection
Commercial status
Quote on verified requirement

Single-product and multi-line requests use the same human-reviewed workflow.

01

Product overview

What this sourcing family is designed to organize.

The BH-60 is a fixed gas detector with a local display and multiple gas-specific sensor options. The reviewed source lists 4–20 mA, RS485 and relay outputs. The exact sensor and explosion-protection documentation must be confirmed for each installation.

Gas Detection
02

Reference configurations

Intake categories from the linked source, pending exact model and SKU mapping.

01BH-60Source reviewed
03

Technical specifications

Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.

AttributeCatalog valueVerification basis
Accuracy / sensitivityNot stated in the reviewed sourceSource-listed — supplier confirmation required
Alarm / output4–20 mA, RS485 and dry-contact output; contact rating listed up to 1 kWSource-listed — supplier confirmation required
Housing / ingress protectionAluminium housing; ingress rating not stated in the reviewed sourceSource-listed — supplier confirmation required
Installation / samplingWall-mounted fixed installationSource-listed — supplier confirmation required
Measurement rangeGas dependent: CO 0–1,000 ppm; O2 0–30 vol%; H2 0–1,000 ppm; H2S 0–100 ppm; CH4 0–5 vol%; combustible 0–100% LEL; other gases availableSource-listed — supplier confirmation required
Product typeFixed gas detector with displaySource-listed — supplier confirmation required
RFQ verification checkConfirm the target gas and range, relay load, local display, mounting conditions and hazardous-area certificateSource-listed — supplier confirmation required
Source brandBoseanSource-listed — supplier confirmation required
Source modelBH-60Source-listed — supplier confirmation required
Source-listed certificationSource-listed Ex db IIC T6 Gb; not independently verifiedSource-listed — supplier confirmation required
Supply / batteryDC 24 V ±10%Source-listed — supplier confirmation required
04

Inputs to include in the RFQ

The more of these inputs you can provide, the fewer rounds of clarification are needed.

01Target gas and expected concentration rangeRFQ input template
Technical document pending
02Portable or fixed installation requirementRFQ input template
Technical document pending
03Alarm, relay and control-system interfaceRFQ input template
Technical document pending
04Required hazardous-area and calibration documentationRFQ input template
Technical document pending
TECHNICAL PURCHASING Q&A

BH-60 Fixed Gas Detector — procurement FAQs

Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.

01What has to be verified before the BH-60 is used in a fixed installation?

Confirm the gas-specific sensor and range, local display configuration, power, 4–20 mA, RS485 or relay output, relay logic and mounting location. A family-level statement about compatible sensors or outputs does not prove the requested combination exists. The quote should also identify the enclosure, calibration method and exact explosion-protection evidence required for the destination and site.

02What must be specified before selecting the sensor and alarm setpoints?

State the target gas, expected concentration and units, possible cross-interferences, background atmosphere, temperature and humidity. Alarm setpoints must come from the approved site risk assessment and applicable requirements, not from a generic catalogue default.

03How should analog, digital and relay outputs be compared?

Start with the receiving system rather than the detector. Record the required 4–20 mA input, RS485 protocol and register map, relay action or alarm-panel interface, along with power, cable distance and failure behaviour. Confirm that the selected transmitter supports the requested output combination simultaneously.

04What calibration and installation evidence should accompany the quote?

Ask for the exact sensor, range, calibration certificate or basis, recommended bump-test and calibration interval, power and output details, enclosure protection and service-access requirements. For fixed equipment, also request the proposed mounting location and hazardous-area documentation needed for review.