Sensepoint XCD Fixed Gas Detector

Fixed gas-detection transmitter with local display, configurable sensor options and analog or Modbus communication.

Source-listed reference data

Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.

Product family ID
GAS-005
Internal family code
GAS-SPXCD
Application route
Gas Detection
Commercial status
Quote on verified requirement

Single-product and multi-line requests use the same human-reviewed workflow.

01

Product overview

What this sourcing family is designed to organize.

The Sensepoint XCD combines a fixed gas sensor and transmitter in one enclosure. The reviewed source lists oxygen, toxic, hydrogen and combustible sensors with 4–20 mA and RS485 Modbus outputs. Hazardous-area compatibility depends on the exact certification variant.

Gas Detection
02

Reference configurations

Intake categories from the linked source, pending exact model and SKU mapping.

01Sensepoint XCDSource reviewed
03

Technical specifications

Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.

AttributeCatalog valueVerification basis
Accuracy / sensitivitySensor dependent; examples include O2 <±0.5 vol%, H2S <±1 ppm, CO <±6 ppm and LEL <±1.5% LELSource-listed — supplier confirmation required
Alarm / output3-wire 4–20 mA, RS485 Modbus and three control relays; optional sink or source configurationSource-listed — supplier confirmation required
Housing / ingress protectionEpoxy-coated ADC12 aluminium or 316 stainless steel; IP66Source-listed — supplier confirmation required
Installation / samplingFixed installation with 2 × M20 or 2 × 3/4 in NPT cable entriesSource-listed — supplier confirmation required
Measurement rangeSensor dependent: O2 up to 25 vol%; H2S 10–100 ppm; CO 100–1,000 ppm; H2 1,000 ppm; NO2 10–50 ppm; LEL ranges; CO2 up to 2 vol%Source-listed — supplier confirmation required
Product typeFixed gas detector and transmitterSource-listed — supplier confirmation required
RFQ verification checkConfirm gas and range, enclosure material, supply voltage, relay logic, cable entry and the exact hazardous-area certificateSource-listed — supplier confirmation required
Source brandHoneywellSource-listed — supplier confirmation required
Source modelSensepoint XCDSource-listed — supplier confirmation required
Source-listed certificationSource-listed UL/c-UL, ATEX and IECEx hazardous-area markings; not independently verifiedSource-listed — supplier confirmation required
Supply / battery12–32 VDC in the specification sheet; the product-page quick specification states 16–32 VDC, so supply compatibility must be confirmedSource-listed — supplier confirmation required
04

Inputs to include in the RFQ

The more of these inputs you can provide, the fewer rounds of clarification are needed.

01Target gas and expected concentration rangeRFQ input template
Technical document pending
02Portable or fixed installation requirementRFQ input template
Technical document pending
03Alarm, relay and control-system interfaceRFQ input template
Technical document pending
04Required hazardous-area and calibration documentationRFQ input template
Technical document pending
TECHNICAL PURCHASING Q&A

Sensepoint XCD Fixed Gas Detector — procurement FAQs

Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.

01What must be fixed in the specification for a Sensepoint XCD installation?

The Sensepoint XCD is a fixed monitoring starting point, so the quote must identify the target gas and sensor, measuring range, transmitter variant, power, output, alarm mapping and mounting method. Confirm whether the site needs analog, Modbus or both, and verify the exact hazardous-area rating and installation documents. A portable leak check and this fixed continuous-monitoring duty are not interchangeable.

02What must be specified before selecting the sensor and alarm setpoints?

State the target gas, expected concentration and units, possible cross-interferences, background atmosphere, temperature and humidity. Alarm setpoints must come from the approved site risk assessment and applicable requirements, not from a generic catalogue default.

03How should analog, digital and relay outputs be compared?

Start with the receiving system rather than the detector. Record the required 4–20 mA input, RS485 protocol and register map, relay action or alarm-panel interface, along with power, cable distance and failure behaviour. Confirm that the selected transmitter supports the requested output combination simultaneously.

04What calibration and installation evidence should accompany the quote?

Ask for the exact sensor, range, calibration certificate or basis, recommended bump-test and calibration interval, power and output details, enclosure protection and service-access requirements. For fixed equipment, also request the proposed mounting location and hazardous-area documentation needed for review.