Gas Detection InstrumentsFAMILY / GAS-001
JL269 Portable Gas Leak Detector
Handheld combustible-gas leak detector with a flexible probe for ppm-level checks on piping, utilities and maintenance work.
Source-listed reference data
Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.
Single-product and multi-line requests use the same human-reviewed workflow.
01
Product overview
What this sourcing family is designed to organize.
The JL269 is a portable leak-sniffing instrument. Source-listed ranges cover methane, propane and hydrogen, with a flexible gooseneck probe and lithium-ion battery. It is presented for leak finding at ppm levels; it is not a percentage-LEL concentration instrument unless the selected sensor and calibration are confirmed.
Gas Detection
02
Reference configurations
Intake categories from the linked source, pending exact model and SKU mapping.
01JL269Source reviewed
03
Technical specifications
Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.
Attribute
Catalog value
Verification basis
Accuracy / sensitivity
Source lists sensitivity better than 50 ppm; repeatability and calibration basis are not stated
Source-listed — supplier confirmation required
Alarm / output
LCD leak indication; source does not state the complete alarm or data-output interface
Source-listed — supplier confirmation required
Housing / ingress protection
Not stated in the reviewed source
Source-listed — supplier confirmation required
Installation / sampling
Natural diffusion with a flexible gooseneck probe
Source-listed — supplier confirmation required
Measurement range
CH4 0–30,000 ppm; C3H8 0–20,000 ppm; H2 up to 10,000 ppm
Source-listed — supplier confirmation required
Product type
Portable combustible-gas leak detector
Source-listed — supplier confirmation required
RFQ verification check
Confirm the target gas, ppm versus percentage-LEL requirement, alarm behavior, calibration certificate and hazardous-area suitability
Source-listed — supplier confirmation required
Source brand
Hanwei Electronics
Source-listed — supplier confirmation required
Source model
JL269
Source-listed — supplier confirmation required
Source-listed certification
No model-specific certification was identified in the reviewed source; company-level statements are not treated as model approval
Source-listed — supplier confirmation required
Supply / battery
DC 3.7 V, 2,500 mAh lithium-ion battery; at least 8 hours
Source-listed — supplier confirmation required
04
Inputs to include in the RFQ
The more of these inputs you can provide, the fewer rounds of clarification are needed.
01Target gas and expected concentration rangeRFQ input template Technical document pending
02Portable or fixed installation requirementRFQ input template Technical document pending
03Alarm, relay and control-system interfaceRFQ input template Technical document pending
04Required hazardous-area and calibration documentationRFQ input template Technical document pending
TECHNICAL PURCHASING Q&A
JL269 Portable Gas Leak Detector — procurement FAQs
Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.
01Is the JL269 a percentage-LEL detector or a ppm leak finder?
Treat the JL269 as a portable combustible-gas leak-finding platform, not automatically as a percentage-LEL concentration instrument. The source-listed methane, propane and hydrogen ranges and the exact sensor determine its usable measurement. The quotation must state the selected range, ppm or %LEL basis, alarm points and calibration before the unit is applied to a concentration or safety task.
02What must be specified before selecting the sensor and alarm setpoints?
State the target gas, expected concentration and units, possible cross-interferences, background atmosphere, temperature and humidity. Alarm setpoints must come from the approved site risk assessment and applicable requirements, not from a generic catalogue default.
03How should analog, digital and relay outputs be compared?
Start with the receiving system rather than the detector. Record the required 4–20 mA input, RS485 protocol and register map, relay action or alarm-panel interface, along with power, cable distance and failure behaviour. Confirm that the selected transmitter supports the requested output combination simultaneously.
04What calibration and installation evidence should accompany the quote?
Ask for the exact sensor, range, calibration certificate or basis, recommended bump-test and calibration interval, power and output details, enclosure protection and service-access requirements. For fixed equipment, also request the proposed mounting location and hazardous-area documentation needed for review.