Industrial instrumentation sourcing · Contact us on WhatsAppProcess, gas and airflow instruments · Review status clearly marked
Gas Detection InstrumentsFAMILY / GAS-001

JL269 Portable Gas Leak Detector

Handheld combustible-gas leak detector with a flexible probe for ppm-level checks on piping, utilities and maintenance work.

Source-listed reference data

Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.

Product family ID
GAS-001
Internal family code
GAS-JL269
Application route
Gas Detection
Commercial status
Quote on verified requirement

Single-product and multi-line requests use the same human-reviewed workflow.

01

Product overview

What this sourcing family is designed to organize.

The JL269 is a portable leak-sniffing instrument. Source-listed ranges cover methane, propane and hydrogen, with a flexible gooseneck probe and lithium-ion battery. It is presented for leak finding at ppm levels; it is not a percentage-LEL concentration instrument unless the selected sensor and calibration are confirmed.

Gas Detection
02

Reference configurations

Intake categories from the linked source, pending exact model and SKU mapping.

01JL269Source reviewed
03

Technical specifications

Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.

AttributeCatalog valueVerification basis
Accuracy / sensitivitySource lists sensitivity better than 50 ppm; repeatability and calibration basis are not statedSource-listed — supplier confirmation required
Alarm / outputLCD leak indication; source does not state the complete alarm or data-output interfaceSource-listed — supplier confirmation required
Housing / ingress protectionNot stated in the reviewed sourceSource-listed — supplier confirmation required
Installation / samplingNatural diffusion with a flexible gooseneck probeSource-listed — supplier confirmation required
Measurement rangeCH4 0–30,000 ppm; C3H8 0–20,000 ppm; H2 up to 10,000 ppmSource-listed — supplier confirmation required
Product typePortable combustible-gas leak detectorSource-listed — supplier confirmation required
RFQ verification checkConfirm the target gas, ppm versus percentage-LEL requirement, alarm behavior, calibration certificate and hazardous-area suitabilitySource-listed — supplier confirmation required
Source brandHanwei ElectronicsSource-listed — supplier confirmation required
Source modelJL269Source-listed — supplier confirmation required
Source-listed certificationNo model-specific certification was identified in the reviewed source; company-level statements are not treated as model approvalSource-listed — supplier confirmation required
Supply / batteryDC 3.7 V, 2,500 mAh lithium-ion battery; at least 8 hoursSource-listed — supplier confirmation required
04

Inputs to include in the RFQ

The more of these inputs you can provide, the fewer rounds of clarification are needed.

01Target gas and expected concentration rangeRFQ input template
Technical document pending
02Portable or fixed installation requirementRFQ input template
Technical document pending
03Alarm, relay and control-system interfaceRFQ input template
Technical document pending
04Required hazardous-area and calibration documentationRFQ input template
Technical document pending
TECHNICAL PURCHASING Q&A

JL269 Portable Gas Leak Detector — procurement FAQs

Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.

01Is the JL269 a percentage-LEL detector or a ppm leak finder?

Treat the JL269 as a portable combustible-gas leak-finding platform, not automatically as a percentage-LEL concentration instrument. The source-listed methane, propane and hydrogen ranges and the exact sensor determine its usable measurement. The quotation must state the selected range, ppm or %LEL basis, alarm points and calibration before the unit is applied to a concentration or safety task.

02What must be specified before selecting the sensor and alarm setpoints?

State the target gas, expected concentration and units, possible cross-interferences, background atmosphere, temperature and humidity. Alarm setpoints must come from the approved site risk assessment and applicable requirements, not from a generic catalogue default.

03How should analog, digital and relay outputs be compared?

Start with the receiving system rather than the detector. Record the required 4–20 mA input, RS485 protocol and register map, relay action or alarm-panel interface, along with power, cable distance and failure behaviour. Confirm that the selected transmitter supports the requested output combination simultaneously.

04What calibration and installation evidence should accompany the quote?

Ask for the exact sensor, range, calibration certificate or basis, recommended bump-test and calibration interval, power and output details, enclosure protection and service-access requirements. For fixed equipment, also request the proposed mounting location and hazardous-area documentation needed for review.