Industrial instrumentation sourcing · Contact us on WhatsAppProcess, gas and airflow instruments · Review status clearly marked
Pressure InstrumentsFAMILY / PRESSURE-003

P100E Digital Pressure Transmitter

Configurable pressure transmitter with analog or RS485 output and selectable accuracy classes.

Source-listed reference data

Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.

Product family ID
PRESSURE-003
Internal family code
PRESSURE-P100E
Application route
Fluid Transfer, Pressure Measurement
Commercial status
Quote on verified requirement
Reference source
Supplier product reference reviewed 2026-11-11

Single-product and multi-line requests use the same human-reviewed workflow.

01

Product overview

What this sourcing family is designed to organize.

The P100E reference series offers a broad pressure range and selectable output and accuracy options. The process connection and wetted configuration must be selected for the specific installation, and the page does not provide an ingress-protection rating.

Fluid TransferPressure Measurement
02

Reference configurations

Intake categories from the linked source, pending exact model and SKU mapping.

No separate configuration has been approved for this family. The buyer request is reviewed against the supplied equipment or drawing.

03

Technical specifications

Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.

AttributeCatalog valueVerification basis
Listed minimum order1 piece; availability to be confirmedSource-listed — supplier confirmation required
Listed trade termFOB; shipping origin and current terms to be confirmedSource-listed — supplier confirmation required
Output options4–20 mA, 0–10 V, 0–5 V, 1–5 V, 0.5–4.5 V or RS485Source-listed — supplier confirmation required
Process connectionM20 × 1.5, G1/4, G1/2, 1/4 NPT or customSource-listed — supplier confirmation required
Product typeDigital pressure transmitterSource-listed — supplier confirmation required
Source brandYUFAVORSource-listed — supplier confirmation required
Source modelP100ESource-listed — supplier confirmation required
Source-listed accuracy reference±1%, ±0.5%, ±0.25%, ±0.15% or ±0.1% FS, depending on configurationSource-listed — supplier confirmation required
Source-listed calibrationUSD 27.40 at 5–49 pieces, USD 26.20 at 50–499 pieces and USD 24.80 at 500+ pieces; reference onlySource-listed — supplier confirmation required
Source-listed priceUSD 28.40 from 1–4 piecesSource-listed — supplier confirmation required
Source-title pressure reference-0.1 MPa through 100 MPa, with the exact selected range to be confirmedSource-listed — supplier confirmation required
Supply9–32 VDC, 12–32 VDC or 5 VDC depending on outputSource-listed — supplier confirmation required
Wetted materialsThe source lists SS304 but does not identify each wetted componentSource-listed — supplier confirmation required
04

Inputs to include in the RFQ

The more of these inputs you can provide, the fewer rounds of clarification are needed.

01Required pressure range and pressure typeRFQ input template
Technical document pending
02Accuracy classRFQ input template
Technical document pending
03Analog or RS485 outputRFQ input template
Technical document pending
04Process thread and wetted-material requirementRFQ input template
Technical document pending
TECHNICAL PURCHASING Q&A

P100E Digital Pressure Transmitter — procurement FAQs

Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.

01Should this pressure family be specified as gauge, absolute or differential pressure?

The measurement basis must be stated explicitly for P100E Digital Pressure Transmitter. Provide the normal, minimum and maximum pressure, whether the reading is referenced to atmosphere, a vacuum or a second pressure port, and the proof-pressure requirement. Do not infer the pressure type from the product name alone.

02What is needed to match the pressure instrument to the control system?

Provide the available supply, controller input or protocol, cable distance, required output, accuracy basis and whether the signal must be analog, digital or both. Also confirm the thread or flange, wetted materials, enclosure protection and any local display, switch or relay requirement.

03Which process conditions can change the required pressure rating?

Pressure spikes, pulsation, water hammer, vacuum, process temperature, ambient temperature, corrosive media and cyclic operation can affect the required sensor, wetted materials and proof-pressure margin. State upset conditions as well as normal operation, then verify the pressure-temperature rating for the exact proposed configuration.

04Can this instrument be used directly in a safety-critical or hazardous-area duty?

That must be established through an application-specific engineering and safety review. The RFQ must state the area classification, calibration, conformity and destination-market requirements. No certification, SIL capability, compatibility or approval should be assumed until the exact model and supporting documents are verified.