Illustrative image. Exact appearance, accessories, finish and markings must be confirmed against the quoted model.
Pressure InstrumentsFAMILY / PRESSURE-010
DPG409 High-Accuracy Digital Pressure Gauge
High-accuracy battery-powered digital gauge with user-selectable voltage or current output.
Source-listed reference data
Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.
Single-product and multi-line requests use the same human-reviewed workflow.
01
Product overview
What this sourcing family is designed to organize.
The DPG409 reference covers low differential-pressure equivalents through 5,000 psi. It combines a digital display with selectable voltage or current output and 316L stainless-steel wetted construction. The source lists NEMA 4X/IP65 protection and a five-point calibration statement that must be confirmed with the quotation.
Equipment RepairPressure Measurement
02
Reference configurations
Intake categories from the linked source, pending exact model and SKU mapping.
No separate configuration has been approved for this family. The buyer request is reviewed against the supplied equipment or drawing.
03
Technical specifications
Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.
Attribute
Catalog value
Verification basis
Ingress protection
NEMA 4X / IP65
Source-listed — supplier confirmation required
Output options
0–5 VDC, 0–10 VDC or 4–20 mA
Source-listed — supplier confirmation required
Process connection
1/4-18 NPT male
Source-listed — supplier confirmation required
Product type
High-accuracy digital pressure gauge with output
Source-listed — supplier confirmation required
Source brand
Omega
Source-listed — supplier confirmation required
Source model
DPG409
Source-listed — supplier confirmation required
Source-listed accuracy reference
±0.08% BSL
Source-listed — supplier confirmation required
Source-listed calibration
Five-point calibration is listed; the applicable traceability and certificate package must be confirmed
Source-listed — supplier confirmation required
Source-title pressure reference
0–10 inH2O through 0–5,000 psi (approximately 0–25 mbar through 0–345 bar), depending on model
Source-listed — supplier confirmation required
Supply
Two 1.5 V alkaline C batteries; analog output requires an external 24 VDC supply
Source-listed — supplier confirmation required
Wetted materials
316L stainless steel
Source-listed — supplier confirmation required
04
Inputs to include in the RFQ
The more of these inputs you can provide, the fewer rounds of clarification are needed.
01Required pressure range and unitsRFQ input template Technical document pending
02Output and control-system requirementsRFQ input template Technical document pending
01Should this pressure family be specified as gauge, absolute or differential pressure?
The measurement basis must be stated explicitly for DPG409 High-Accuracy Digital Pressure Gauge. Provide the normal, minimum and maximum pressure, whether the reading is referenced to atmosphere, a vacuum or a second pressure port, and the proof-pressure requirement. Do not infer the pressure type from the product name alone.
02What is needed to match the pressure instrument to the control system?
Provide the available supply, controller input or protocol, cable distance, required output, accuracy basis and whether the signal must be analog, digital or both. Also confirm the thread or flange, wetted materials, enclosure protection and any local display, switch or relay requirement.
03Which process conditions can change the required pressure rating?
Pressure spikes, pulsation, water hammer, vacuum, process temperature, ambient temperature, corrosive media and cyclic operation can affect the required sensor, wetted materials and proof-pressure margin. State upset conditions as well as normal operation, then verify the pressure-temperature rating for the exact proposed configuration.
04Can this instrument be used directly in a safety-critical or hazardous-area duty?
That must be established through an application-specific engineering and safety review. The RFQ must state the area classification, calibration, conformity and destination-market requirements. No certification, SIL capability, compatibility or approval should be assumed until the exact model and supporting documents are verified.