Industrial instrumentation sourcing · Contact us on WhatsAppProcess, gas and airflow instruments · Review status clearly marked
Pressure InstrumentsFAMILY / PRESSURE-004

A-10 Pressure Transmitter

Compact industrial pressure transmitter with broad pressure coverage and several electrical-output options.

Source-listed reference data

Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.

Product family ID
PRESSURE-004
Internal family code
PRESSURE-A10
Application route
Equipment Repair, Pressure Measurement
Commercial status
Quote on verified requirement

Single-product and multi-line requests use the same human-reviewed workflow.

01

Product overview

What this sourcing family is designed to organize.

The A-10 reference transmitter covers gauge, absolute and vacuum ranges. Depending on range and configuration, the source identifies 316L wetted parts, analog outputs, selectable electrical connections and IP65 or IP67 protection. The stated accuracy is a non-linearity value, so the measurement error must be checked against the selected range and standard.

Equipment RepairPressure Measurement
02

Reference configurations

Intake categories from the linked source, pending exact model and SKU mapping.

No separate configuration has been approved for this family. The buyer request is reviewed against the supplied equipment or drawing.

03

Technical specifications

Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.

AttributeCatalog valueVerification basis
Ingress protectionCommonly IP65, with certain cable or connector options listed at IP67Source-listed — supplier confirmation required
Listed minimum order1 unit in the source configurator; current stock and lead time to be confirmedSource-listed — supplier confirmation required
Output options4–20 mA, DC 0–10 V or DC 0–5 VSource-listed — supplier confirmation required
Process connectionG1/4 A according to DIN EN ISO 1179-2, 1/4 NPT and other optionsSource-listed — supplier confirmation required
Product typeIndustrial pressure transmitterSource-listed — supplier confirmation required
Source brandWIKASource-listed — supplier confirmation required
Source modelA-10Source-listed — supplier confirmation required
Source-listed accuracy reference≤ ±0.25% or ±0.5% of span, depending on the selected model; overall measurement error must be checked in the datasheetSource-listed — supplier confirmation required
Source-listed priceFrom USD 153.04; configuration and commercial terms varySource-listed — supplier confirmation required
Source-title pressure referenceGauge pressure 0–0.05 to 0–1,000 bar, plus absolute and vacuum variantsSource-listed — supplier confirmation required
SupplyDC 8–30 V for 4–20 mA, with optional DC 8–35 V depending on configurationSource-listed — supplier confirmation required
Wetted materials316L below 10 bar; 316L and PH-grade steel at 10 bar and above, according to the source datasheetSource-listed — supplier confirmation required
04

Inputs to include in the RFQ

The more of these inputs you can provide, the fewer rounds of clarification are needed.

01Pressure basis, selected range and maximum pressureRFQ input template
Technical document pending
02Required analog outputRFQ input template
Technical document pending
03Electrical connectorRFQ input template
Technical document pending
04Wetted-material and accuracy requirementRFQ input template
Technical document pending
TECHNICAL PURCHASING Q&A

A-10 Pressure Transmitter — procurement FAQs

Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.

01Should this pressure family be specified as gauge, absolute or differential pressure?

The measurement basis must be stated explicitly for A-10 Pressure Transmitter. Provide the normal, minimum and maximum pressure, whether the reading is referenced to atmosphere, a vacuum or a second pressure port, and the proof-pressure requirement. Do not infer the pressure type from the product name alone.

02What is needed to match the pressure instrument to the control system?

Provide the available supply, controller input or protocol, cable distance, required output, accuracy basis and whether the signal must be analog, digital or both. Also confirm the thread or flange, wetted materials, enclosure protection and any local display, switch or relay requirement.

03Which process conditions can change the required pressure rating?

Pressure spikes, pulsation, water hammer, vacuum, process temperature, ambient temperature, corrosive media and cyclic operation can affect the required sensor, wetted materials and proof-pressure margin. State upset conditions as well as normal operation, then verify the pressure-temperature rating for the exact proposed configuration.

04Can this instrument be used directly in a safety-critical or hazardous-area duty?

That must be established through an application-specific engineering and safety review. The RFQ must state the area classification, calibration, conformity and destination-market requirements. No certification, SIL capability, compatibility or approval should be assumed until the exact model and supporting documents are verified.