Pressure InstrumentsFAMILY / PRESSURE-001

HPT200 Industrial Pressure Transmitter

Configurable industrial pressure transmitter for pressure and level measurement, with multiple electrical outputs and process connections.

Source-listed reference data

Model, technical values and commercial references below come from the supplied supplier sources captured for intake. Manufacturer sourcing, configuration, certification, stock, MOQ, price and lead time are confirmed before an order.

Product family ID
PRESSURE-001
Internal family code
PRESSURE-HPT200
Application route
Fluid Transfer, Pressure Measurement
Commercial status
Quote on verified requirement

Single-product and multi-line requests use the same human-reviewed workflow.

01

Product overview

What this sourcing family is designed to organize.

The HPT200 reference series is a configurable pressure transmitter. The source material lists pressure and level ranges, several analog and digital outputs, multiple process connections, 316L wetted materials and IP65 to IP67 protection. Final range, process compatibility and documentation are confirmed for each RFQ.

Fluid TransferPressure Measurement
02

Reference configurations

Intake categories from the linked source, pending exact model and SKU mapping.

No separate configuration has been approved for this family. The buyer request is reviewed against the supplied equipment or drawing.

03

Technical specifications

Source-listed values are shown as intake references and remain subject to configuration and supplier confirmation.

AttributeCatalog valueVerification basis
Ingress protectionIP65 to IP67, configuration dependentSource-listed — supplier confirmation required
Output options4–20 mA, 0–5 V, 0–10 V, 0.5–4.5 V, dual 4–20 mA, 4–20 mA + HART or RS485 Modbus RTUSource-listed — supplier confirmation required
Process connectionG1/4, G1/2, 1/8 NPT, 1/4 NPT, 1/2 NPT and custom optionsSource-listed — supplier confirmation required
Product typeIndustrial pressure transmitter / pressure sensorSource-listed — supplier confirmation required
Source brandHolykellSource-listed — supplier confirmation required
Source modelHPT200Source-listed — supplier confirmation required
Source-listed accuracy referenceTypical ≤ ±0.25% FS; optional ≤ ±0.1% FS at 25°C, including non-linearity, repeatability and hysteresisSource-listed — supplier confirmation required
Source-title pressure referenceApproximately -1 to 1,000 bar depending on series; customized level ranges are listed up to 50 mSource-listed — supplier confirmation required
SupplyDepends on output: 8–30, 12–30 or 13–30 VDC, or 5 VDC ±5%Source-listed — supplier confirmation required
Wetted materials316L stainless-steel diaphragm; 316L body and sensor with optional 316 or SUS321; standard silicone oil with optional fluorine oilSource-listed — supplier confirmation required
04

Inputs to include in the RFQ

The more of these inputs you can provide, the fewer rounds of clarification are needed.

01Process medium and expected pressure rangeRFQ input template
Technical document pending
02Required output and control-system interfaceRFQ input template
Technical document pending
03Thread or process-connection detailsRFQ input template
Technical document pending
04Required documentation and destination-market acceptanceRFQ input template
Technical document pending
TECHNICAL PURCHASING Q&A

HPT200 Industrial Pressure Transmitter — procurement FAQs

Short answers to the technical and commercial checks buyers most often need before this family can be quoted accurately.

01Should this pressure family be specified as gauge, absolute or differential pressure?

The measurement basis must be stated explicitly for HPT200 Industrial Pressure Transmitter. Provide the normal, minimum and maximum pressure, whether the reading is referenced to atmosphere, a vacuum or a second pressure port, and the proof-pressure requirement. Do not infer the pressure type from the product name alone.

02What is needed to match the pressure instrument to the control system?

Provide the available supply, controller input or protocol, cable distance, required output, accuracy basis and whether the signal must be analog, digital or both. Also confirm the thread or flange, wetted materials, enclosure protection and any local display, switch or relay requirement.

03Which process conditions can change the required pressure rating?

Pressure spikes, pulsation, water hammer, vacuum, process temperature, ambient temperature, corrosive media and cyclic operation can affect the required sensor, wetted materials and proof-pressure margin. State upset conditions as well as normal operation, then verify the pressure-temperature rating for the exact proposed configuration.

04Can this instrument be used directly in a safety-critical or hazardous-area duty?

That must be established through an application-specific engineering and safety review. The RFQ must state the area classification, calibration, conformity and destination-market requirements. No certification, SIL capability, compatibility or approval should be assumed until the exact model and supporting documents are verified.