Read this as a documented comparison
The first decision is not which model is best. It is whether the task calls for a portable inspection tool or a fixed transmitter that monitors a defined location continuously. Only after that choice should the buyer compare gas configuration, range, alarm response, mounting, electrical interface and calibration evidence.
This report uses public product pages already recorded in the Indulynx catalogue. It treats each statement as source-listed until the exact model, sensor code and current datasheet have been verified. It does not convert marketing copy or a family name into an approval.
Compare the duty before the model
Portable detectors support leak finding, inspection rounds and temporary work areas. Fixed detectors support continuous monitoring, plant-level alarms and planned sensor maintenance at a defined point. A portable instrument should not be treated as a substitute for permanent area protection.
For every candidate, state the target gas, expected concentration, alarm action, background atmosphere, measurement location and who will verify calibration. These inputs determine whether a leak finder, personal detector, oxygen meter or fixed transmitter is even in scope.
| Family | Primary documented role | Source-listed configuration clues | Evidence to confirm before quote |
|---|---|---|---|
| JL269 | Portable combustible-gas leak finding | Methane, propane and hydrogen ranges; flexible probe | Exact sensor and range; ppm versus %LEL scope; calibration and certification variant |
| BH90E | Portable combustible-gas leak inspection | Source lists 0–10,000 ppm, audible/visual/vibration alarms | Exact Ex marking, sensor, alarm points, calibration certificate and replacement parts |
| JL270 | Portable combustible-gas measurement | Source lists custom ppm and catalytic %LEL options; Bluetooth; IP66 | Selected sensor range, calibration gas, wireless function and certification package |
| Dräger Pac 8000 | Personal single-gas monitoring | Gas-specific toxic, oxygen or carbon dioxide configuration; IP68 enclosure statement | Sensor code, measuring range, alarm setpoints, calibration and approved region |
| Sensepoint XCD | Fixed continuous gas detection | Oxygen, toxic, hydrogen and combustible options; 4–20 mA and RS485 Modbus statement | Gas sensor, transmitter variant, wiring, alarm mapping and hazardous-area certification |
| Dräger Polytron 8100 EC | Fixed electrochemical toxic/oxygen detection | More than 100 electrochemical sensor combinations; analog and optional digital communication | Installed sensor, range, output electronics, calibration adapter, service interval and approval |
| YT-95H / YT-95H-X | Fixed gas-specific or %LEL detection | Gas-specific options; 4–20 mA, RS485 and relay statements; wall, pipe or flow-cell mounting | Exact model suffix and sensor, output combination, mounting kit, enclosure and approval |
| BH-60 | Fixed wall-mounted gas detection | Gas-specific options; 4–20 mA, RS485 and relay statements; local display | Sensor and range, transmitter version, relay logic, power, enclosure and certification |
The table summarizes catalogue reference data. It is not a ranking, test result or statement of cross-brand equivalence.
Portable families answer different questions
JL269, BH90E and JL270 appear in the catalogue as combustible-gas inspection tools, but their documented features differ. JL269 is presented around leak finding with a flexible probe. BH90E is presented around a ppm range and multiple local alarm indicators. JL270 is presented with configurable ppm or catalytic %LEL options and data-transfer features.
The Pac 8000 is a different class of portable product: a personal single-gas detector configured for a specific toxic gas, oxygen or carbon dioxide measurement. That distinction matters because a leak finder guided along a pipe and a personal detector worn in a work area create different evidence, alarm and calibration requirements.
Fixed families differ by sensor and interface scope
Sensepoint XCD, Polytron 8100 EC, YT-95H and BH-60 are fixed starting points, but their documented sensor architectures and interfaces are not interchangeable statements. Sensepoint XCD and Polytron 8100 EC are described through manufacturer sensor options and field communication. YT-95H and BH-60 are presented with gas-specific configurations and multiple analog, digital and relay outputs.
The buying decision should therefore name the installed sensor, the output used by the control system, the alarm action and the service method. When the family supports several variants, a family-level description is not enough to issue a purchase order.
Build a comparable evidence pack
A useful RFQ gives every supplier the same application facts and asks for the same evidence. This prevents a quick quotation from winning simply because it omits a sensor code, certification, calibration accessory or interface module required by the project.
Review completed proposals against the original requirement. If a supplier offers an alternative sensor, range, enclosure or communication option, record the difference and ask whether it changes installation, alarm mapping, calibration or destination-market acceptance.
- Target gas, expected concentration range and alarm-response action.
- Portable inspection or fixed continuous-monitoring duty.
- Exact sensor code, measuring range and calibration-gas basis.
- Power, output, controller and alarm-panel interface.
- Mounting location, access, enclosure and hazardous-area requirement.
- Required certification, calibration record, spare parts and service interval.
- Destination country and any site-specific standards or approval procedure.
Sources reviewed
These sources support the documented statements in this article. A source link does not establish availability, authorization, certification for a selected variant, or suitability for a specific application.
- JL269 portable gas leak detectorHW Sensor product reference · accessed 2026-11-11
- BH90E portable gas leak detectorBosean · accessed 2026-11-11
- JL270 portable gas leak detectorHW Sensor · accessed 2026-11-11
- Dräger Pac 8000Dräger · accessed 2026-11-11
- Sensepoint XCD fixed gas detectorHoneywell · accessed 2026-11-11
- Dräger Polytron 8100 ECDräger · accessed 2026-11-11
- YT-95H online gas detectoriSafeGas · accessed 2026-11-11
- BH-60 fixed gas detectorBosean · accessed 2026-11-11
This guide helps collect inputs. It does not substitute for an approved drawing, datasheet, engineering review, or application-specific compatibility check.